Motor Connecting Cables
2YSLCY-JB/2YSLCYK-JB 9YSLCY-JB PENDANT CABLE  

Mineral insulated cables

Constant Wattage Heating Cable up to 200 °C

Application

Vessels, piping, valves

Food processing industry

Frost protection and temperature maintenance on pumps

Standard

IEC 62395-2, EN 60519-10.

Voltage Rating

230V

CABLE CONSTRUCTION

Bus wire

Insulation: Silicone.

Heating conductor

Protective: Copper braid

Outer sheath: Silicone.

Mechanical and Thermal Properties

Nominal temperature: 200℃

Minimum installation temperature: -60℃

Minimum start-up temperature: -60℃

Bus wire cross section: 2x1.50 mm²

Cable Parameter

APPROX.
Dimensions mm

Contact spacing m

Nominal output W/m

Maximum heating circuit length m

at 50 °C

at 150 °C

5.25x9.75

1.0

10

198

147

5.25x9.75

1.0

20

139

102.5

5.25x9.75

1.0

30

98

82.5

5.25x9.75

1.0

40

73.5

70.5